Trendnet TI-F11SFP

SKU: TI-F11SFP

hardened Industrial 100/1000Base-T to SFP Media Converter

15 ΗΜΕΡΕΣ

Περιγραφή

Description

TRENDnet’s TI-F11SFP is a reliable IP30 rated 100/ 1000 Base-T to SFP media converter with hardened components rated for extreme industrial environments.

Set 100 or 1000 Mbps throughput speeds, Auto Negotiation, and Link Fault Pass Through (LFP) using the front panel dip switches.

Dual redundant power inputs (power supply sold separately: TI-M6024) with overload current protection support zero downtime applications.

Specifications 
Standards     IEEE 802.3
IEEE 802.3u
IEEE 802.3ab
IEEE 802.3z
IEEE 802.3x
Device Interface        1 x Gigabit port
1 x Gigabit SFP slot
4-pin removable terminal block
LED indicators
DIP Switch
DIN-Rail mount
Wall mount
Grounding point
Data Transfer Rate    Ethernet: 10Mbps (half duplex), 20Mbps (full duplex)
Fast Ethernet: 100Mbps (half duplex), 200Mbps (full duplex)
Gigabit: 2000Mbps (full duplex)
Fiber: 2000Mbps (full duplex)
Performance  Data RAM Buffer: 1MB
Jumbo Frame: 16KB
Special Features       Hardened components rated for extreme temperatures
12 – 56V DC power input
Alarm Relay
Auto-Negotiation
Auto store and forward architecture
Automatic address learning and address aging
ESD 8KV and Surge 2KV protection
Power         Input: 12 – 56V DC
Compatible power supply: TI-M6024 (sold separately)
Max. consumption:
1.8W @12VDC
2.16W @24VDC
3W @48V
3.36W @56VDC
Terminal Block      Power input: 4-pin terminal block
Wire range: 0.34mm^2 to 2.5mm^2
Solid wire (AWG): 12-24/14-22
Stranded wire (AWG): 12-24/14-22
Torque: 5 lb. – In / 0.5Nm / 0.56 Nm
Wire strip length: 7-8mm
DIP Switch  1: Turns LFP (Link Fault Pass Through) on/off
2: Set SFP speed to 100Mbps or 1000Mbps
MTBF 510,304 hours
Housing      IP30 metal case
DIN-Rail mount
Wall mount
Grounding point
8KV ESD protection
2KV surge protection
Operating Temperature -40° – 75° C (-40° – 167° F)
Operating Humidity Max. 95% non-condensing
Dimensions 103 x 80 x 31mm (4.1 x 3.2 x 1.2 in.)
Weight 142g (5 oz.)
Certifications        CE
FCC
Shock (IEC 60068-2-27)
Freefall (IEC 60068-2-32)
Vibration (IEC 60068-2-6)
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-4-5